Skip to content
Technical compliance

Engineered compliance, documented evidence.

Next Generation construction is only as strong as the discipline behind it. We engineer compliance into the system from RIBA Stage 2, document the evidence at every hold point, and hand over a complete record at Stage 6.

Engineering disciplines

Six performance areas, coordinated from concept.

Fire, acoustic, airtightness and thermal continuity are not handed to the contractor on site — they are engineered into the manufactured element.

01

DfMA coordination

Design for Manufacture & Assembly is led from RIBA Stage 2 — interfaces, tolerances and module geometries locked before manufacturing release.

02

Interface geometry

Module-to-module, module-to-structure and module-to-services interfaces engineered with documented tolerances on every joint.

03

Fire compartmentation

Fire strategy engineered into the panel and module build-ups — specialist fire engineer engaged from concept stage.

04

Acoustic performance

Inter-tenancy and wet-room acoustic separation designed and tested against project-specific targets.

05

Airtightness

Factory-applied membranes, taped joints and documented connection sequences deliver consistent test results.

06

Thermal continuity

Continuous insulation strategies — designed to eliminate cold bridging through interfaces and connections.

Quality assurance

Five inspection layers from raw material to handover.

Every layer documented against the evidence pack. Every record traceable to the unit it covers.

  1. 01

    Material certification

    Mill certificates, supplier QA records and conformity certificates captured against each batch.

  2. 02

    In-process inspection

    Dimensional, weld and finish inspection at defined hold points within the production line.

  3. 03

    Pre-dispatch sign-off

    Module / panel functionally tested and signed off before release to logistics.

  4. 04

    Site receipt inspection

    Independent site inspection on receipt — tolerances and damage logged against each unit.

  5. 05

    Post-installation commissioning

    Fire stopping, acoustic, airtightness and M&E commissioning evidenced before handover.

RIBA stage hold points

Where we lock the build, stage by stage.

Each hold point produces a documented decision. No stage progresses until the previous stage's evidence is complete.

RIBA STAGE 202

Concept Design

DfMA strategy locked. System selection (LSF / volumetric / hybrid). Fire and acoustic specialists engaged. Module size envelope defined against transport and craneage.

RIBA STAGE 303

Spatial Coordination

Interface geometry frozen. Service routing through manufactured elements coordinated. Carbon and energy strategy committed. Fixed-price proposal issued.

RIBA STAGE 404

Technical Design

Manufacturing-issue drawings released. Evidence pack structure agreed. QA inspection plan issued.

RIBA STAGE 505

Manufacturing & Construction

Production line inspection cycle live. Site interface coordination weekly. Hold-point reviews documented.

RIBA STAGE 606

Handover

Evidence pack issued. As-built BIM model handed over. O&M, warranty and aftercare schedule transferred.

Accreditations & Standards

Certifications and frameworks engineered into every project.

From environmental management to healthcare and educational standards, our systems are built to meet — and exceed — the certifications that matter to UK and international developers.

01

ISO14001 Certified

Environmental management

02

BREEAM Accreditable

Sustainability rating

03

NHBC Accreditation Compliant

Residential warranty

04

Building Regulations Compliant

UK statutory requirements

05

Healthcare HTM/HBN Compliant

Clinical environments

06

Educational Standards Compliant

DfE & EFA frameworks

07

Passive House Attainable

Ultra-low energy performance

08

100% Recyclable

Circular economy ready

Next Steps

Bring our precision-engineered solutions to your next façade project

Talk to us about deploying our capability and delivery disciplines to your scheme.